BOSCH REXROTH
R901342033
$416.30 USD
- BOSCH REXROTH
- Material:R901342033
- Model:HM 20-2X/400-C-K35 GO2
Quantity in stock: 1
The Bosch Rexroth HM 20-2X/400-C-K35 (R901342033) is a high-performance pressure transducer designed for monitoring and controlling hydraulic pressures in demanding applications. This transducer is capable of converting measured pressure into a normalized, linear electrical output signal, ensuring accurate and reliable pressure readings. It features a robust thin film measuring cell and all components that come into contact with media are constructed from durable stainless steel, enhancing its longevity and resistance to harsh conditions. The HM 20-2X/400-C-K35 offers operational safety through its high bursting pressure capacity and built-in protections against reversed polarity, overvoltage, and short circuits. Its accuracy class is 0.5, with an impressive non-repeatability of less than 0.1%, ensuring precise measurements every time. The device can operate within a wide temperature range from -40 to +125 degrees Celsius, making it suitable for use in various environments. This model has received marine approval from DNVGL for all variants with current output, indicating its suitability for maritime applications. It belongs to component series X and can handle maximum operating pressures up to 400 bar. The available pressure ratings include 100, 160, 250, 315, 400, 600, and up to 1000 bar. Additionally, the HM 20-2X/400-C-K35 is cULus listed, confirming its compliance with North American safety standards. With its comprehensive range of features and certifications, the Bosch Rexroth HM 20-2X/400-C-K35 pressure transducer is an essential component for hydraulic systems requiring precise pressure monitoring and control across various industries and applications.
Unpacked Weight: 0.0605 kg
Pressure transducers are used to monitor and control hydraulic pressures. They transform the measured pressure into a normalized, linear, electrical output signal.
Data Sheet | Download Data Sheet |
Productgroup ID | 9,10,11,12,13,14 |
01 |
02 |
03 |
04 |
05 |
06 |
||||
HM20 |
– |
2X |
/ |
– |
– |
K35 |
01 |
Pressure transducer |
HM20 |
02 |
Component series 20 ... 29 (20 ... 29: unchanged installation dimensions and pin assignments) |
2X |
03 |
10 bar |
10 |
50 bar |
50 |
|
100 bar |
100 |
|
160 bar |
160 |
|
250 bar |
250 |
|
315 bar |
315 |
|
400 bar |
400 |
|
630 bar1) |
630 |
|
04 |
Current output 4 to 20 mA 2) |
C |
Voltage output 0.1 to 10 V |
H |
|
05 |
Connector, 4-pole, M12x1 |
K35 |
06 |
Without throttle element |
ohne Bez. |
Throttle element (corresponds to 0.3 mm nozzle) 3), 4) |
N |
1) | Only available with throttle element |
2) | With marine approval DNV-GL |
3) | Only available for versions with 250, 315, 400 and 630 bar |
4) | Highly dynamic effects in like pressure peaks or cavitation in hydraulic systems may damage the measuring cell. For these applications, devices with integrated throttle element [version "-N"] in the process interface have to be used. |
Replacement seal ring |
|
Designation |
Material number |
Seal ring NBR |
R900012467 |
Cable sets or mating connectors are not included in the scope of delivery; please order separately.
General
Component series |
2X |
Eingangsgrößen
Operating voltage 1) |
US |
16 … 36 VDC | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Residual ripple |
UPP |
2.5 V (40 to 400 Hz) | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Maximum current consumption 2) |
Imax |
mA |
≤ 12 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Isolation resistance |
R |
MΩ |
> 100 (500 VDC) | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Pressure measuring ranges |
pN |
bar |
10 | 50 | 100 | 160 | 250 | 315 | 400 | 630 | 10 | 50 | 100 | 160 | 250 | 315 | 400 | 630 | 10 | 50 | 100 | 160 | 250 | 315 | 400 | 630 | 10 | 50 | 100 | 160 | 250 | 315 | 400 | 630 | 10 | 50 | 100 | 160 | 250 | 315 | 400 | 630 | 10 | 50 | 100 | 160 | 250 | 315 | 400 | 630 | 10 | 50 | 100 | 160 | 250 | 315 | 400 | 630 | 10 | 50 | 100 | 160 | 250 | 315 | 400 | 630 |
1) | With cULus: max. of 30 VDC is admissible |
2) | With voltage output |
Output parameters
Output signal |
admissible load |
Current |
ISig |
4 … 20 mA, RA = (US - 8.5 V) / 0.0215 A with RA in Ω and US in V | |
Voltage |
USig |
0.1 … 10 V, RA > 2 kΩ | |||
Setting time (10 ... 90 %) |
t |
ms |
< 1 | ||
Accuracy class 1) |
% |
< 0.5 | |||
Temperature coefficient |
Zero point and range |
< 0.1 % / 10 K | |||
Hysteresis 2) |
% |
< 0.15 | |||
Long-term drift (1 year) under reference conditions |
% |
< 0.1 |
1) | Related to the complete measurement range, including non-linearity, hysteresis, zero point and end value deviation (corresponds to the measuring deviation according to IEC 61298-2) |
2) | Related to the temperature range -20 … 80 °C |
Ambient conditions
Ambient temperature range |
ϑ |
°C |
-40 … +85 |
Storage temperature range |
ϑ |
°C |
-40 … +100 |
Hydraulic fluid temperature range |
ϑ |
°C |
-40 … +90 |
Other characteristics
Pressure port 1) |
G1/4 according to DIN 3852 form E, seal ring according to DIN 3869-14 | |||
Material |
Throttle |
1.4305 | ||
Housing |
V4A (1.4404), PEI, HNB | |||
in contact with the medium |
1.4542, 1.4305, NBR | |||
Pressure media 2) |
HL, HLP, HFC, nitrogen, others upon request | |||
Tightening torque range |
Measurement ranges > 400 bar |
MA |
Nm |
20 … 25 |
Measurement ranges ≥ 400 bar |
MA |
Nm |
25 … 30 | |
Anschlussart |
4-pole M12 connector at the housing | |||
Type of protection according to EN 60529 |
IP65 / IP67 with mating connector correctly mounted and locked | |||
Weight |
m |
kg |
0.06 | |
Life cycle |
60 million load cycles or 60000 h | |||
Admissible shock and vibration loads according to DIN EN 60068-2-27 |
15 g / 11 ms / 3 axes | |||
Sine test according to DIN EN 60068-2-6:2008 |
10 ... 2000 Hz / maximum 10 g / 10 cycles / 3 axes | |||
Noise test according to DIN EN 60068-2-64 |
20 … 2000 Hz / 14 g RMS / 42 g peak / 24 h / 3 axes | |||
Electro-magnetic compatibility |
EMC EN 61000-4-2 ESD |
4 kV CD / 8 kV AD with BWK B | ||
EMC EN 61000-4-3 HF radiated |
10 V / m (80 ... 2700 MHz) with BWK A | |||
EMC EN 61000-4-4 Burst |
2 kV with BWK B | |||
EMC EN 61000-4-5 Surge |
1 kV / 42 Ω with BWK B | |||
EMC EN 61000-4-6 HF line-bound |
10 Veff (150 kHz ... 80 MHz) with BWK A | |||
EMC EN 61000-4-8 Magnetic field 50/60 Hz |
100 A/m with BWK A | |||
EMC EN 61000-4-9 Magnetic field pulsed |
1000 A/m with BWK A | |||
EMC EN 55016-2-1 Interference voltage |
0.15 ... 30 MHz, class A, EN 55022 | |||
EMC EN 55016-2-3 Radio interference field strength |
30 ... 1000 MHz, class B, EN 55022 | |||
Conformity |
CE according to the EMC directive | |||
Further tests |
cULus-listed |
1) | Thorough bleeding must be ensured |
2) | Maximum of 300 bar is admissible |
For applications outside these parameters, please consult us!
Voltage |
Current (two-wire system) |
Values for US, RA and USig, see Technical data |
Values for US, RA and USig, see Technical data |
Dimensions in mm
1 |
Pressure port G1/4 male thread |
2 |
Seal ring |
3 |
4-pole M12 connector |
Mating connectors for sensors and valves with connector “K24”, “K35” and “K72”, M12 x 1, with assembled connection line, cable shielded
4P M12 +
Mating connectors for sensors and valves with connector “K24”, “K35” and “K72”, M12 x 1, with assembled connection line, cable shielded
4P M12 +
For sensors and valves with connector “K24”, “K35” and “K72” Cable sets M12, 4-pole, line cross-section 0.34 mm2Data sheet