You are using an outdated browser. For a faster, safer browsing experience, upgrade for free today.

BOSCH REXROTH
R978021618


$6,716.30 USD
  • BOSCH REXROTH
  • Material:R978021618
  • Model:VT-HACD-DPQ-2X/CMCRETROFIT

Quantity in stock: 0

01

02

03

04

05

06

07

VT-HACD-DPQ

1

2X

/

V0

/

1

0

01

Digital controller card

VT-HACD-DPQ

02

One axis

1

03

Component series 20 ... 29 (20 ... 29: unchanged installation and connection dimensions)

2X

04

Basic unit

V0

05

With display

1

06

Without bus connection

0

CANopen

C

DeviceNet

D

07

Without valve output stage

0

General

Component series

2X

Voltage supply

Operating voltage

UB

24 VDC

Operating voltage

Lower limit value

UB(t)min

V

21

Upper limit value

UB(t)max

V

30

Current consumption

Imax

150 mA

Fuse

IS

4 A time-lag

Analog inputs

Number

6

Voltage inputs

Range

U

0 to 10 V or ±10 V (configurable)

Input resistance

Re

100 kΩ, > 10 MΩ for input AI 1

Resolution

5 mV for range ±10 V, 2.5 mV for range 0...10 V

Non-linearity

mV

< 10

Current inputs

Range

I

0...20 mA or 4...20 mA (configurable)

Input resistance

Re

100 Ω

Leakage current

Iv

0.15 % (with 500 Ω between pin AI x- and 0 V)

Resolution

5 μA

Digital inputs

Signal

log 0

0 to 5 V

log 1

16 V to UB

Analog outputs

Number

3

AO1 voltage output

Output voltage

U

0 to 10 V or ±10 V (configurable)

Current, max.

Imax

mA

10

Load, min.

RLmin

1

Resolution

1.25 mV (14 bit)

Residual ripple

±15 mV (without noise)

AO1 current output

Current

I

0...20 mA or 4...20 mA (configurable)

Load, max.

Rmax

Ω

500

Resolution

1.25 μ

Residual ripple

±15 µA (without noise)

AO2/AO3 voltage output

Output voltage

U

±10 V

Current, max.

Imax

mA

10

Load, min.

RLmin

1

Resolution

10 mV (11 bit)

Residual ripple

±25 mV (without noise)

Digital outputs

Number

8

Logic level

log 0 (low) ≤ 2 V; log 1 (high) ≤ UB; Imax = 20 mA, maximum load capacity C = 0.047 μF

Connection

flexible conductor up to 1.5 mm2

Reference potential for all signals

GND

Signal

log 0

0 to 5 V

log 1

16 V to UB

Current, max.

Imax

mA

30

Digital position transducer (encoder)

SSI transducer

Line receiver/driver

RS485

Other characteristics

Reference voltage

U

V

± 10

Load, max.

Imax

mA

30

Residual ripple

mV

< 20

Scanning time

t

ms

2

Interface, serial

RS 232 (front plate), D-Sub socket

Anschlussart

64-pin male connector, DIN 41612, form G

Local bus, distance to the furthermost device, max.

I

max. 280 m line length

Operating temperature range

ϑ

°C

​0 … +50

Storage temperature range

ϑ

°C

-20 … +70

Weight

m

g

0.2

For applications outside these parameters, please consult us!

Block diagram

technical illustration-R978021618-Actual value recording via SSI encoder, incremental or analog position measurement system possible Free configuration of the valve control spool Control loop adjustment Jog mode controlled Separate menus for injection, holding pressure and back pressure Pressure transition via:<br>
- Position<br>
- Internal mold pressure<br>
- Hydraulic pressure via position<br>
- Discrete input Enable input and OK output ±10 V reference voltage output Front display with keys to display and change parameters as well as for diagnosis purposes. RS232 serial interface Up to 32 controller cards can be interconnected for parameterization and diagnosis via the local bus internal or analog profile I/O configuration

1

Analog inputs, voltage or current

2a

SSI encoder

2b

Incremental encoder

3

Enable and digital input

4

Setting analog inputs

5

Internal profile

6

Feedback selection

7

Controller

8

control spool configuration

9

Analog outputs (voltage or current)

10

OK output and digital outputs

11

CAN interface, optional

12

Local bus

Pin assignment of the D-Sub socket on the front panel

technical illustration-R978021618-Actual value recording via SSI encoder, incremental or analog position measurement system possible Free configuration of the valve control spool Control loop adjustment Jog mode controlled Separate menus for injection, holding pressure and back pressure Pressure transition via:<br>
- Position<br>
- Internal mold pressure<br>
- Hydraulic pressure via position<br>
- Discrete input Enable input and OK output ±10 V reference voltage output Front display with keys to display and change parameters as well as for diagnosis purposes. RS232 serial interface Up to 32 controller cards can be interconnected for parameterization and diagnosis via the local bus internal or analog profile I/O configuration

Dimensions in mm

technical illustration-R978021618-Actual value recording via SSI encoder, incremental or analog position measurement system possible Free configuration of the valve control spool Control loop adjustment Jog mode controlled Separate menus for injection, holding pressure and back pressure Pressure transition via:<br>
- Position<br>
- Internal mold pressure<br>
- Hydraulic pressure via position<br>
- Discrete input Enable input and OK output ±10 V reference voltage output Front display with keys to display and change parameters as well as for diagnosis purposes. RS232 serial interface Up to 32 controller cards can be interconnected for parameterization and diagnosis via the local bus internal or analog profile I/O configuration