***Disclaimer: The following summary contains information gathered from various sources such as product descriptions, technical specifications and catalogs. While efforts have been made to provide accurate details, inaccuracies may occur. It is advised to verify all information by contacting Sun Hydraulics directly.***
The Sun Hydraulics PVJCCCN (PVJCCCN) is a sophisticated externally drained, pilot-operated pressure reducing/relieving valve designed to maintain a consistent reduced pressure at port 1 from a higher primary pressure at inlet port 2. It features a full-flow relief function that channels from port 1 to tank port 3, with an option for remote control via pilot or two-way valves by draining the pilot section at port 4. This design ensures insensitivity to pressure at tank port 3. The valve is engineered with maximum stability and low hysteresis, exhibiting exceptionally flat pressure-flow characteristics and minimal deadband transition between reducing and relieving modes. The valve operates effectively within specified differential pressures based on adjustment ranges: ranges D, E, N, and Q are suited for up to 2000 psi (140 bar), while ranges A, B, and H handle up to 3000 psi (210 bar) differentials. For ranges C and W, the maximum inlet pressure can reach up to 5000 psi (350 bar). The maximum allowable pressure at tank port 3 is limited to 3000 psi (210 bar), and any pressure on drain port 4 directly adds to the valve setting at a ratio of 1:1 but should not exceed 5000 psi (350 bar). Incorporating Sun's floating style construction minimizes risks of internal part binding due to excessive installation torque or machining variations. The design accommodates an adjustment mechanism with up to 55 clockwise turns for setting increases. With factory settings established under blocked control conditions, this model supports a maximum operating pressure of up to 5000 psi (350 bar) and achieves a control pilot flow between 15 - 20 in\u00b3/min (0.25 - 0.33 L/min). It also includes specific installation guidelines such as torque specifications for locknut adjustments ensuring reliable performance in hydraulic systems where precise pressure regulation is critical.
The Sun Hydraulics PVJCCCN (PVJCCCN) is a sophisticated externally drained, pilot-operated pressure reducing/relieving valve designed to maintain a consistent reduced pressure at port 1 from a higher primary pressure at inlet port 2. It features a full-flow relief function that channels from port 1 to tank port 3, with an option for remote control via pilot or two-way valves by draining the pilot section at port 4. This design ensures insensitivity to pressure at tank port 3. The valve is engineered with maximum stability and low hysteresis, exhibiting exceptionally flat pressure-flow characteristics and minimal deadband transition between reducing and relieving modes. The valve operates effectively within specified differential pressures based on adjustment ranges: ranges D, E, N, and Q are suited for up to 2000 psi (140 bar), while ranges A, B, and H handle up to 3000 psi (210 bar) differentials. For ranges C and W, the maximum inlet pressure can reach up to 5000 psi (350 bar). The maximum allowable pressure at tank port 3 is limited to 3000 psi (210 bar), and any pressure on drain port 4 directly adds to the valve setting at a ratio of 1:1 but should not exceed 5000 psi (350 bar). Incorporating Sun's floating style construction minimizes risks of internal part binding due to excessive installation torque or machining variations. The design accommodates an adjustment mechanism with up to 55 clockwise turns for setting increases. With factory settings established under blocked control conditions, this model supports a maximum operating pressure of up to 5000 psi (350 bar) and achieves a control pilot flow between 15 - 20 in\u00b3/min (0.25 - 0.33 L/min). It also includes specific installation guidelines such as torque specifications for locknut adjustments ensuring reliable performance in hydraulic systems where precise pressure regulation is critical.
Externally drained, pilot-operated pressure reducing/relieving valves reduce a high primary pressure at the inlet (port 2) to a constant reduced pressure at port 1, with a full-flow relief function from port 1 to tank (port 3). Draining the pilot section at port 4 makes these valves insensitive to pressure at tank (port 3) and provides a means for remote control by pilot or 2-way valves.
- Maximum pressure at port 3 should be limited to 3000 psi (210 bar).
- Pilot operated valves exhibit very low dead-band transition between reducing and relieving modes.
- Recommended maximum inlet pressure is determined by the adjustment range. Ranges D, E, N, and Q are tested with a 2000 psi (140 bar) maximum differential between inlet and reduced pressure. Ranges A, B, and H are tested with a 3000 psi (210 bar) maximum differential between inlet and reduced pressure. Ranges C and W are tested with 5000 psi (350 bar) of inlet pressure.
- Pilot operated valves exhibit exceptionally flat pressure/flow characteristics, are very stable and have low hysteresis.
- Pressure on the drain (port 4) is directly additive to the valve setting at a 1:1 ratio and should not exceed 5000 psi (350 bar).
- Pilot operated reducing, reducing/relieving valves by nature are not fast acting valves. For superior dynamic response, consider direct acting valves.
- By controlling the pressure at the drain (port 4), the effective setting of the valve can be increased over the nominal valve setting.
- Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.
Cavity | T-24A |
Series | 4 |
Capacity | 80 gpm320 L/min. |
Factory Pressure Settings Established at | blocked control port (dead headed)blocked control port (dead headed) |
Maximum Operating Pressure | 5000 psi350 bar |
Control Pilot Flow | 15 - 20 in³/min.0,25 - 0,33 L/min. |
Adjustment - Number of Clockwise Turns to Increase Setting | 55 |
Valve Hex Size | 1 5/8 in.41,3 mm |
Valve Installation Torque | 350 - 375 lbf ft474 - 508 Nm |
Adjustment Screw Internal Hex Size | 5/32 in.4 mm |
Locknut Hex Size | 9/16 in.15 mm |
Locknut Torque | 80 - 90 lbf in.9 - 10 Nm |
Model Weight | 3.10 lb1,40 kg |
Seal kit - Cartridge | Viton: 990-024-006 |
Show FAQ
Additional Resources
- QuickDesign with SmartConnect Offers Drag-and-Drop Schematic Tool
- Sun Expands Corrosion-Resistant Solutions
- Series 4 PLUS Cartridges Offer Higher Flows with Lower Pressure Losses
- Sun Offers Zinc-Nickel Plating for Corrosion Resistance
- Sun Cartridges with EPDM Seals
- Manufacturing Sun Cartridge Cavities
- Reducing and Reducing/Relieving Valves
- Cartridges: Materials of Construction
- Fluid and Temperature Recommendations
- Performance Data
- Sun's Floating Style Screw-In Cartridge
- Units of Measure, Settings, and Conversions
- Sun Model Code Explanation; 999-901-334
- Cavity Information (S-171) and Tooling
Notes:
- Maximum pressure differentials for spring ranges: A and B are 3000 psi (210 bar) D and E are 2000 psi (140 bar) W is 5000 psi (350 bar) inlet pressure