SUN HYDRAULICS
RVCD8DN


$129.10 USD

Tags:

  • SUN HYDRAULICS
  • Material:RVCD8DN
  • Model:RVCD-8DN
  • Summary:Cartridge

Quantity in stock: 0

***Disclaimer: The following summary contains information gathered from various sources such as product descriptions, technical specifications and catalogs. While efforts have been made to provide accurate details, inaccuracies may occur. It is advised to verify all information by contacting Sun Hydraulics directly.***
The Sun Hydraulics RVCD8DN (Material Number: RVCD8DN) is a high-performance, normally closed modulating valve designed with an integral pilot control cavity. This valve is ventable, externally drained, and features a balanced piston design. It effectively regulates pressure by allowing the modulating element to open to tank port 2 when the inlet port 1 reaches the pilot control cartridge setting, throttling flow as needed. The pilot control cavity is compatible with any T8A pressure control cartridge, which controls the pressure differential between inlet port 1 and drain port 4. Additionally, the vent port 3 offers flexibility for remote pilot or two-way valve control. This valve can handle maximum pressure at port 2 and is ideal for cross-port relief circuits. However, it is not recommended for load holding applications due to spool leakage. The main stage orifice is safeguarded by a robust 150-micron stainless steel screen. Pressure at port 4 should not exceed 5000 psi (350 bar) as it directly influences the valve setting in a 1:1 ratio. For installation, ensure that the main stage valve is torqued correctly before attaching the T8A pilot control valve. The '8' control option allows direct integration of the pilot control valve into the relief cartridge via the T8A cavity; these cartridges are available separately and include various operation options like electroproportional and solenoid. Cartridges configured with EPDM seals are suitable for phosphate ester fluids but should avoid petroleum-based fluids to prevent seal damage. The Sun floating style construction minimizes internal binding risks due to installation torque variations or machining discrepancies. With a capacity of up to 15 gpm (60 L/min) and rapid response time of approximately 10 ms, this versatile valve enhances hydraulic system performance across various applications while maintaining stability under high-pressure conditions.

This valve is a normally closed modulating element that incorporates an integral pilot control cavity. It is ventable, externally drained, and is a balanced piston design. The pilot control cavity will accept any T-8A pressure control cartridge. When the pressure at the inlet (port 1) reaches the pilot control cartridge setting, the modulating element starts to open to tank (port 2), throttling flow to regulate the pressure. The pilot cartridge's setting determines the difference in pressure between the inlet (port 1) and the drain (port 4). The vent port (port 3) that tees in between the main piston and pilot control cartridge, allows the modulating element to also be controlled by remote pilot or 2-way valves.

  • Will accept maximum pressure at port 2; suitable for use in cross port relief circuits.
  • Main stage orifice is protected by a 150 micron stainless steel screen.
  • Not suitable for use in load holding applications due to spool leakage.
  • Pressure at port 4 is directly additive to the valve setting at a 1:1 ratio and should not exceed 5000 psi (350 bar).
  • NOTE: With the -8 control option, the main stage valve should first be installed to the correct torque value. The T-8A pilot control valve should then be installed into the main stage valve to its required torque value.
  • The -8 control option allows the pilot control valve to be incorporated directly into the end of the relief cartridge via the T-8A cavity. These pilot control cartridges are sold separately and include electro-proportional, solenoid, air pilot, and hydraulic pilot operation. See Pilot Control Cartridges.
  • Cartridges configured with EPDM seals are for use in systems with phosphate ester fluids. Exposure to petroleum based fluids, greases and lubricants will damage the seals.
  • Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.

CavityT-21A
Series1
Capacity15 gpm60 L/min.
Maximum Operating Pressure5000 psi350 bar
Control Pilot Flow7 - 10 in³/min.0,11 - 0,16 L/min.
Response Time - Typical10 ms10 ms
Pilot Control CavityT-8AT-8A
Main stage leakage at 110 SUS (24 cSt)2 in³/min.@1000 psi30 cc/min.@70 bar
Valve Hex Size7/8 in.22,2 mm
Valve Installation Torque30 - 35 lbf ft41 - 47 Nm
Model Weight.40 lb0,20 kg
Seal kit - CartridgeViton: 990-021-006

Show FAQ

Additional Resources



Notes:
  • Compound cartridge (pilot and main stage) assembly information is provided for reference only. Cartridges must be ordered separately and assembled at point of use.