Flow dividers are sliding-spool, pressure-compensated devices used to split oil flow to two different branches of a circuit in a designated ratio. These valves are suitable for applications that use the following: unidirectional hydraulic motors, hydraulic cylinders where flow division in one direction only is required, and multiple circuits that are serviced from one pump supply.

  • All flow divider and divider/combiner cartridges are physically interchangeable (i.e. same flow path, same cavity for a given frame size).
  • Operating characteristics cause the leg of the circuit with the greatest load to receive the higher percentage of flow in dividing mode. If a rigid mechanism is used to tie actuators together, the lead actuator may pull the lagging actuator and cause it to cavitate.
  • In applications involving rigid mechanisms between multiple actuators, operating inaccuracy will cause the eventual lock-up of the system. If the mechanical structure is not designed to allow for the operating inaccuracy inherent in the valve, damage may occur.
  • In motor circuits, rigid frames or mechanisms that tie motors together, and/or complete mechanical synchronized motion of the output shaft of the motors, either by wheels to the pavement or sprockets to conveyors, will contribute to cavitation, lock-up and/or pressure intensification.
  • Variations in speed and lock-up can be attributed to differences in motor displacement, motor leakage, wheel diameter variance and friction of wheels on the driving surface.
  • This valve is a divider only; any attempt to flow backwards through the valve is not advised.
  • Dividers with unequal ratios have the higher flow at port 4.
  • Below the minimum flow rating there is not enough flow for the valve to modulate. It is effectively a tee. If flow starts at zero and rises, there will be no dividing control until the flow reaches the minimum rating.
  • Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.

Cavity T-33A
Series 3
Capacity 6 - 30 gpm23 - 120 L/min.
Maximum Operating Pressure 5000 psi350 bar
Divisional Accuracy at Minimum Input Flow ±6.5%±6.5%
Divisional Accuracy at Max Input Flow ±3.5%±3.5%
Pressure Drop at Minimum Rated Input Flow 30 psi2 bar
Pressure Drop at Maximum Rated Input Flow 250 psi18 bar
Rated Input Flow with 50/50 Split 6 - 30 gpm23 - 120 L/min.
Rated Input Flow with 40/60 Split 5 - 25 gpm19 - 95 L/min.
Rated Input Flow with 33/67 Split 4.4 - 22 gpm17 - 85 L/min.
Valve Hex Size 1 1/4 in.31,8 mm
Valve Installation Torque 150 - 160 lbf ft203 - 217 Nm
Model Weight 1.40 lb0,65 kg
Seal kit - Cartridge Viton: 990-033-006