Hydrotech Acquires Isaacs
Hydrotech ecommerce supports the continental US only

BOSCH REXROTH
Z3DR6VP2-1X/200MSV
R901160168
Pressure Reducing Valves

Pressure valves: Z.DR 6V.-1X

$359.00

BOSCH REXROTH

MATERIAL:  R901160168

SUMMARY:  Pressure valves: Z.DR 6V.-1X

Add to Cart

Valve type Z3DR are pilot-operated 3-way pressure reducing valves in sandwich plate design with pressure limitation of the actuator. They serve for reduction and control of secondary pressure.

The valves basically consist of pilot control valve (1) and housing (2) including main stage. The secondary pressure is set via the adjustment type (3).

Rexroth pilot-operated pressure reducing valves feature flat discharge pressure curves, high stability and low hysteresis.

Version "MS" enables measurement and monitoring of the set secondary pressure via a pressure load cell at the measuring port (4) (refer to Dimensions).

If the secondary pressure at actuator port P① further exceeds the set value, the third line to tank port T is opened by the valve. This way, the actuator channel is protected against inadmissible pressure rise.

technical illustration-Z3DR6VP2-1X/200MSV-Pressure valves: Z.DR 6V.-1X

component side

plate side

01

02

03

04

05

06

07

08

09

10

11

12

Z

3

DR

6

V

P

-

1X

/

01

Sandwich plate valve

Z

02

3-way version

3

03

Pressure reducing valve

DR

04

Size 6

6

05

Pilot-operated

V

Pressure reduction

06

In channel P➀

P

Adjustment type

07

Spindle with internal hexagon and protective cap ("J3" version without protective cap)

2

Lockable rotary knob with scale

1)

3

08

Component series 10 ... 19 (10 ... 19: unchanged installation and connection dimensions)

1X

Pressure rating

09

Set pressure up to 50 bar

50

Set pressure up to 100 bar

100

Set pressure up to 200 bar

200

Set pressure up to 315 bar

315

Pressure measuring port G1/4

10

Without pressure measuring port

no code

With pressure measuring port (secondary pressure)

MS

Corrosion resistance

11

None

no code

Improved corrosion protection (240 h salt spray test according to EN ISO 9227); (only version "2")

J3

Seal material

12

NBR seals

no code

FKM seals

V

Observe compatibility of seals with hydraulic fluid used.

1) H-Key with material no. R900008158 is included in the scope of delivery.

Notice:

For valve types for use in explosive areas, refer to data sheet 07011.

general

Size

6

Weight

Version "2"

kg

1.3

Version "3"

kg

1.4

Installation position

any

Ambient temperature range

°C

-15 … +80

MTTFD values according to EN ISO 13849 1)

yrs

​75 … ​600
1) For further details, see data sheet 08012

hydraulic

Size

6

Maximum operating pressure

bar

350

Maximum return flow pressure 1)

bar

160

Maximum set pressure

Version

50

bar

50

100

bar

100

200

bar

200

315

bar

315

Maximum flow

l/min

60

Hydraulic fluid

see table

Hydraulic fluid temperature range

°C

-15 … +80

Viscosity range 2)

mm²/s

10 … 500

Maximum admissible degree of contamination of the hydraulic fluid 3)

Class 20/18/15 according to ISO 4406 (c)
1) Ideally depressurized to the tank. Counter pressure adds to the set pressure.
2) Preferably 50 … 120 mm2/s
3) The cleanliness classes specified for the components must be adhered to in hydraulic systems. Effective filtration prevents faults and simultaneously increases the life cycle of the components. For the selection of the filters, see www.boschrexroth.com/filter.

Hydraulic fluid

Classification

Suitable sealing materials

Standards

Data sheet

Mineral oils

HL, HLP

NBR, FKM

DIN 51524

90220

Bio-degradable

​1)

Insoluble in water

HETG

NBR, FKM

ISO 15380

90221

HEES

FKM

Soluble in water

HEPG

FKM

ISO 15380

Flame-resistant

Water-free

HFDU (glycol base)

FKM

ISO 12922

90222

HFDU (ester base)

1)

FKM

Containing water

1)

HFC (Fuchs Hydrotherm 46M, Petrofer Ultra Safe 620)

NBR

ISO 12922

90223

Important information on hydraulic fluids:

For more information and data on the use of other hydraulic fluids, please refer to the data sheets above or contact us. There may be limitations regarding the technical valve data (temperature, pressure range, life cycle, maintenance intervals, etc.). The ignition temperature of the hydraulic fluid used must be 40 K higher than the maximum surface temperature. Flame-resistant – containing water: Maximum operating pressure 210 bar, otherwise increased cavitation erosion Life cycle as compared to operation with mineral oil HL, HLP 30 … 100 % Maximum hydraulic fluid temperature 60 °C
1) In connection with the corrosion-protected version “J3”, small amounts of dissolved zinc may get into the hydraulic system.

For applications outside these parameters, please consult us!

(measured with HLP46, ϑOil = 40 ±5 °C)

Δp-qv characteristic curves

Pressure rating 50 bar

technical illustration-Z3DR6VP2-1X/200MSV-Pressure valves: Z.DR 6V.-1X

Pressure rating 100 bar

technical illustration-Z3DR6VP2-1X/200MSV-Pressure valves: Z.DR 6V.-1X

Pressure rating 200 bar

technical illustration-Z3DR6VP2-1X/200MSV-Pressure valves: Z.DR 6V.-1X

Pressure rating 315 bar

technical illustration-Z3DR6VP2-1X/200MSV-Pressure valves: Z.DR 6V.-1X

Without pressure measuring port "no code"

technical illustration-Z3DR6VP2-1X/200MSV-Pressure valves: Z.DR 6V.-1X

With pressure measuring port "MS"

technical illustration-Z3DR6VP2-1X/200MSV-Pressure valves: Z.DR 6V.-1X

component side

plate side

Dimensions in mm

technical illustration-Z3DR6VP2-1X/200MSV-Pressure valves: Z.DR 6V.-1X
technical illustration-Z3DR6VP2-1X/200MSV-Pressure valves: Z.DR 6V.-1X

Required surface quality of the valve contact surface

component side – porting pattern according to ISO 4401-03-02-0-05 (with locating hole Ø4 x 4 mm deep)

plate side – Porting pattern according to ISO 4401-03-02-0-05 (with locating hole Ø3 x 5 mm deep for locking pin ISO 8752-3x8-St, material no. R900005694, separate order)

1

Name plate

2

Adjustment type "2" (spindle with internal hexagon SW8 and lock nut SW24)

3

Adjustment type "3"

4.1

Without measuring port (standard)

4.2

Measuring port (version "MS"); when loosening the plug screw (SW6 internal hexagon, tightening torque MA = 20 Nm ±10 %), hold the SW24 reducing piece in place

5

Valve mounting bores

6

Identical seal rings for ports A, B, P, T (plate side)

7

Space required to remove the key

8

Protective cap (not included with version "J3")

Valve mounting screws (separate order)

4 hexagon socket head cap screws ISO 4762 - M5 - 10.9

Notices:

Length and tightening torque of the valve mounting screws must be calculated according to the components mounted under and over the sandwich plate valve. The dimensions are nominal dimensions which are subject to tolerances.

Denomination

Part number

Protective cap

R900135501

Locking pin ISO 8752-3x8-St

R900005694